Water Quality in Colts Neck, NJ (08691)

EPA violation data for public water systems serving ZIP code 08691.

Based on EPA compliance data. Not a substitute for an official water quality report from your utility.

16,607

Population

41

Water Systems

193

Violations (5yr)

6

Health-Based

Location

Loading map...

Water Systems Serving This Area (41)

Nj American Water - Coastal North

All resolved
Surface water 377,613 people served
1 violation (5yr) · All resolved
Lead tested: 2 ppb (limit: 15 ppb)

Trenton Water Works

3 health-based
Surface water 217,000 people served
65 violations (5yr) · 3 health-based · All resolved
Lead tested: 4 ppb (limit: 15 ppb)

Aqua Nj - Hamilton Square

Purchased surface water 39,128 people served
16 violations (5yr)

Aqua Nj - Eastern Division

Groundwater 12,000 people served
9 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Lawrence

Groundwater under influence of surface water 8,655 people served
14 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Woolwich

All resolved
Purchased surface water 6,271 people served
3 violations (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Allentown Water Dept

All resolved
Groundwater 2,000 people served
1 violation (5yr) · All resolved
Lead tested: 0.99 ppb (limit: 15 ppb)

Aqua Nj - Wallkill

All resolved
Groundwater 1,050 people served
1 violation (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Califon

Groundwater 936 people served
9 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Roosevelt Water Dept

All resolved
Groundwater 880 people served
1 violation (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Riegel Ridge

Groundwater 621 people served
9 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Tranquility Springs

1 health-based
Groundwater under influence of surface water 599 people served
7 violations (5yr) · 1 health-based
Lead tested: 0 ppb (limit: 15 ppb) Copper tested: 1600 ppb (limit: 1300 ppb)

Aqua Nj - Spartan Village

Groundwater 594 people served
4 violations (5yr)
Lead tested: 2.8 ppb (limit: 15 ppb)

Aqua Nj - Vernon

All resolved
Groundwater 515 people served
1 violation (5yr) · All resolved
Lead tested: 4.1 ppb (limit: 15 ppb)

Red Lion Plaza

All resolved
Groundwater 330 people served
1 violation (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Robbinsville Twp - Newtown Village

All resolved
Purchased surface water 300 people served
5 violations (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - California Village

Groundwater 300 people served
4 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Seaview Harbor

Groundwater 300 people served
4 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Hanover Mobile Village

Groundwater 285 people served
2 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj - Bunnvale

Groundwater 252 people served
6 violations (5yr)

Aqua Nj - Bear Brook

Groundwater 226 people served
8 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Four Acres Inc

Groundwater 200 people served
0 violations

Aqua Nj - Warren Glen

All resolved
Groundwater 192 people served
1 violation (5yr) · All resolved
Lead tested: 1.2 ppb (limit: 15 ppb)

Aqua Nj - Summit Lake

All resolved
Groundwater 177 people served
5 violations (5yr) · All resolved
Lead tested: 5.4 ppb (limit: 15 ppb)

Aqua Nj - Fox Hill

All resolved
Groundwater 172 people served
1 violation (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Professor'S Hard Cider

1 health-based
Groundwater 162 people served
1 violation (5yr) · 1 health-based

Aqua Nj - Brainards

All resolved
Groundwater 135 people served
1 violation (5yr) · All resolved
Lead tested: 0 ppb (limit: 15 ppb)

Plumsted Retail Center C/O Jesse Bell

All resolved
Groundwater 96 people served
1 violation (5yr) · All resolved

Aqua Nj/Deep Well Terr

Groundwater 85 people served
0 violations

Aqua Nj California Village 2

Groundwater 80 people served
0 violations

Aqua Nj Cliffside Park

Groundwater 80 people served
1 violation (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Aqua Nj California Village 3

Groundwater 76 people served
0 violations

Fish Net

Groundwater 75 people served
0 violations

Aqua Nj - Riegelsville

Purchased groundwater 62 people served
2 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Irenes Windsor Diner

Groundwater 50 people served
0 violations

Aqua Nj - Harkers Hollow

Groundwater 40 people served
7 violations (5yr)
Lead tested: 0 ppb (limit: 15 ppb)

Edinburg Hotel

Groundwater 30 people served
0 violations

Pennington Office Park-B

1 health-based
Groundwater 25 people served
2 violations (5yr) · 1 health-based · All resolved

Phyllis' Windsor Diner

Groundwater 25 people served
0 violations

Vahlco Corp

Groundwater 25 people served
0 violations

Millstone Turf Inc

Groundwater 25 people served
0 violations

Contaminants Found

Lead and Copper RuleHealth-Based

Lead and copper testing requirement. Lead exposure can cause developmental harm in children.

80 violations
Has active
Revised Total Coliform RuleHealth-Based

Missed testing deadlines — not a detection of bacteria.

26 violations
Has active
TTHMHealth-Based
7 violations
All resolved
Interim Enhanced Surface Water Treatment RuleHealth-Based
4 violations
All resolved
Surface Water Treatment RuleMonitoring
13 violations
All resolved
Total Haloacetic Acids (HAA5)Monitoring
5 violations
All resolved
Consumer Confidence RuleMonitoring

Annual water quality report delivery requirement.

3 violations
All resolved
Radium-228Monitoring
3 violations
All resolved
Combined Radium (-226 and -228)Monitoring
3 violations
All resolved
Gross Alpha, Excl. Radon and UMonitoring
3 violations
All resolved
Radium-226Monitoring
3 violations
All resolved
Combined UraniumMonitoring
3 violations
All resolved
ETHYLENE DIBROMIDEMonitoring
3 violations
All resolved
1,2-DIBROMO-3-CHLOROPROPANEMonitoring
3 violations
All resolved
NitrateMonitoring

At high levels, nitrate can cause blue baby syndrome in infants.

2 violations
All resolved
E. COLIMonitoring
2 violations
Has active
ChlorineMonitoring

Used to disinfect water — generally safe at regulated levels.

2 violations
All resolved
ArsenicMonitoring

A naturally occurring element that can cause cancer and other health effects at high levels.

2 violations
All resolved
Xylenes, TotalMonitoring
1 violation
All resolved
Vinyl chlorideMonitoring
1 violation
All resolved
trans-1,2-DichloroethyleneMonitoring
1 violation
All resolved
cis-1,2-DichloroethyleneMonitoring
1 violation
All resolved
1,2,4-TrichlorobenzeneMonitoring
1 violation
All resolved
StyreneMonitoring
1 violation
All resolved
p-DichlorobenzeneMonitoring
1 violation
All resolved
1,1,2-TrichloroethaneMonitoring
1 violation
All resolved
TetrachloroethyleneMonitoring
1 violation
All resolved
1,1,1-TrichloroethaneMonitoring
1 violation
All resolved
o-DichlorobenzeneMonitoring
1 violation
All resolved
1,2-DichloropropaneMonitoring
1 violation
All resolved
EthylbenzeneMonitoring
1 violation
All resolved
1,1-DichloroethyleneMonitoring
1 violation
All resolved
CHLOROBENZENEMonitoring
1 violation
All resolved
DICHLOROMETHANEMonitoring
1 violation
All resolved
TolueneMonitoring
1 violation
All resolved
TrichloroethyleneMonitoring
1 violation
All resolved
1,2-DichloroethaneMonitoring
1 violation
All resolved
BenzeneMonitoring
1 violation
All resolved
Carbon tetrachlorideMonitoring
1 violation
All resolved
Public NoticeMonitoring
1 violation
All resolved
NitriteMonitoring

Similar to nitrate — harmful to infants at high levels.

1 violation
All resolved
Groundwater RuleMonitoring
1 violation
All resolved

Lead & Copper Levels

Lead (Pb)

Within limit
2 ppb measured Action level: 15 ppb

Sampled: Jul 2025

Copper (Cu)

Exceeds limit
1600 ppb measured Action level: 1300 ppb

Sampled: Jul 2024

How Does This Compare?

Colts Neck (08691) has more violations than 98% of US ZIP codes. The national average is 18.87 violations per ZIP over 5 years. This ZIP has 193.

Fewer violations 98th percentile More violations

Recommended Water Filters

Based on health-based violations detected in your area, these filter types are commonly used to address similar contaminants. Consult your water utility's Consumer Confidence Report for the most current data.

Reverse Osmosis System

Highly effective at removing heavy metals, dissolved solids, and a wide range of contaminants. Recommended for homes with lead or arsenic concerns.

Targets:Lead, Copper, Arsenic, Mercury, Cadmium

Look for:NSF/ANSI 58 certified

Activated Carbon Filter

Excellent for removing chlorine, chloramine, and disinfection byproducts like THMs and HAAs. Available as pitcher filters, countertop, or under-sink units.

Targets:THMs, HAAs, Chlorine, Chloramine, Taste & Odor

Look for:NSF/ANSI 42 & 53 certified

UV Water Purifier

Uses ultraviolet light to neutralize bacteria, viruses, and parasites without chemicals. Ideal for homes with microbial contamination concerns.

Targets:E. coli, Coliform, Giardia, Cryptosporidium

Look for:NSF/ANSI 55 (Class A) certified

Always look for filters certified by NSF International for the specific contaminants you want to remove. This is general educational information, not an endorsement of any specific product.

Nearby ZIP Codes

Check Another ZIP Code